[[Image:S25_stecker_ab.jpg|Stecker ab]] |
[[Image:S25_stecker_ab.jpg|Stecker ab]] |
||
solder the |
solder the cables to the appropriate pins of the socket board and use the shrinkable tubing as insulation<br> |
||
[[Image:Buchsenleiste_geloetet.jpg|Buchsenleiste angeloetet]]<br> |
[[Image:Buchsenleiste_geloetet.jpg|Buchsenleiste angeloetet]]<br> |
||
connect the cable to the wgt<br> |
connect the cable to the wgt<br> |
Revision as of 20:53, 8 January 2006
Serial Connector for WGT634U
Tools:
- Torxschraubendreher/screwdriver T 8
- Knipex, or any other wire cutting pliers
- Lötkolben/soldering iron
- Schrumpfschlauch/shrinkable tubing
www.reichelt.de:
- BL 1X10G 2,54 - 10pol. socket board (Buchsenleiste, gerade, RM 2,54) (you need only four pins -> Knipex, one side marked with soldering iron)
or maybe better
BL 1X20W 2,54 - 20pol. Buchsenleiste, gewinkelt, RM 2,54
- DATENKABEL S25 - für alle Siemens C/M/S 25/35/45 (contains level converter (Pegelwandler) (5V->3.3V))
You have to open the mobile phone side plug.
before:
after (red cable is not connected, colouring can differ):
remove the plug and remember the colour mapping. look here for details pin mapping (DATA OUT=TX, DATA IN=RX)
1 = GND, 5 = DATA OUT, 6 = DATA IN
solder the cables to the appropriate pins of the socket board and use the shrinkable tubing as insulation
connect the cable to the wgt