Revision as of 21:10, 4 January 2006
Serial Connector for WGT634U
Tools:
- Torxschraubendreher/screwdriver T 8
- Knipex
- Lötkolben/soldering iron
- Schrumpfschlauch/shrinkable tubing
www.reichelt.de:
- BL 1X10G 2,54 - 10pol. Buchsenleiste, gerade, RM 2,54 (you need only four pins -> Knipex, one side marked with soldering iron)
or maybe better
BL 1X20W 2,54 - 20pol. Buchsenleiste, gewinkelt, RM 2,54
- DATENKABEL S25 - für alle Siemens C/M/S 25/35/45 (contains voltage level changer (5V->3.3V)
You have to open the mobile phone side plug.
before:
after (red cable is not connected, colouring can differ):
remove the plug and remember the colour mapping. look here for details pin mapping (DATA OUT=TX, DATA IN=RX)
solder the "Buchsenleiste" and use the shrinkable tubing
connect the cable to the wgt